Labcritics
DynaPro Plate Reader 4 Dynamic Light Scattering Instrument
Dynamic Light Scattering Particle Size Analysis DLS

DynaPro Plate Reader 4 Dynamic Light Scattering Instrument

Manufacturer: Waters | Wyatt Technology

SKU: DynaPro Plate Reader 4

Description

The DynaPro Plate Reader 4 is a high-throughput dynamic light scattering (DLS) instrument configured for the automated screening of macromolecules and nanoparticles. It measures key parameters including hydrodynamic size, concentration, aggregation state, and sample stability. The system enables fully automated operation; after loading samples, measurements proceed without further user intervention. It is compatible with standard disposable well plates in 96, 384, or 1536-well formats. For integration into larger automated systems, the instrument can be connected to plate handlers and liquid-handling robots. Typical measurement times range from 5 to 60 seconds per well. Analysis is performed using an 830 nm laser, and the system can characterize particles within a size range of 0.5 nanometers to 1000 nanometers. The instrument's physical dimensions are 36 cm in width, 60 cm in depth, and 25 cm in height. This platform is well-suited for rapidly screening processing or formulation conditions, particularly in fields like biopharmaceutical development.

Specifications

ItemDynaPro Plate Reader 4 Dynamic Light Scattering Instrument
CompanyWaters | Wyatt Technology
Catalog NumberDynaPro Plate Reader 4
Dimensions(WxDxH) 36 x 60 x 25 cm
QuantityEA
TypeDynamic Light Scattering / Static Light Scattering
Particle Size0.5 to 1000 nm
Measuring TimeMeasurement Time: 5 to 60 seconds per well830 nm
Plate Formats96, 384 or 1536 well plates
Sample Volume4 µL to 150 µL
Temperature Range4 °C to 85 °C
Measuring Range0.5 to 1000 nm (hydrodynamic radius); 1 to 1000 kDa (molecular weight). Particle concentration measurement is size-dependent.
ApplicationsDevelop stable biopharmaceuticals, assess viral vector titer and aggregation, optimize protein buffers for crystallization, SAXS or chromatography, formulate theranostic nanoparticles, discover small-molecule and peptide inhibitors of protein-protein interactions
Wavelength(s)830 nm
SensitivityDLS: 0.125 mg/mL of lysozyme; SLS: 1 mg/mL of BSA
Detector(s)Linearized avalanche photodiode for dynamic and static light scattering
Light Source830 nm, fiber-coupled diode laser
Sample TypeProteins, polymers, and nanoparticles including viruses, liposomes, gene vectors, nanoemulsions, etc.
Interface162 mm high-resolution, color LCD multi-touch-screen display, and DYNAMICS® host software